Loading... Please wait...
Features
Applications
| The 35-3000RK (A) series is a compact sample draw detector assembly with a built-in pump that accepts a 24VDC input. This unit features a NEMA 4X enclosure making it dust, water and corrosion resistant. It also features a flowmeter with adjustable flow and a low flow alarm, which warns of any obstructions or restrictions in the flow system. Combustibles, oxygen, hydrogen sulfide and carbon monoxide versions are available with or without a 4-20 mA transmitter. The 35-3000RK (A) is also available with both LEL and oxygen sensors in one unit. The 35-3000RK (A) is capable of single person calibrations and remote sampling at up to 5,000 ft. from a controller, and interfacing to any RKI or third party control system (utilizing a 4-20 mA feedback signal). Large versions of this efficient sample draw system are available with up to four sensors, LEL, O2, H2S and CO all in one enclosure. This is a very cost effective way of monitoring for several gases that may be in the same place. |
![]()
| Part # | LEL 35-3000RKA-LEL | O2 35-3000RKA-O2 | H2S 35-3000RKA-H2S |
|---|---|---|---|
| Min Operating Voltage | 23 VDC | ||
| Max Operating Voltage | 30 VDC | ||
| Max Current Draw | 250 mA | 200 mA | |
| Signal Output | 4 mA at 0% LEL 20 mA at 100% LEL | 4 mA at 0 % Oxygen 20 mA at 25% Oxygen | 4 mA at 0 ppm H2S 20 mA at 100 ppm H 2 S |
| Response Time | 30 seconds to 90% of concentration | 20 seconds to 90% of concentration | 45 seconds to 90% of concentration |
| Operating Environment | |||
| Location | Indoor or outdoor | ||
| Temperature | 30 to 120° F | ||
| Humidity | 0 - 99% RH, non condensing | ||
| Housing | Wall mounting grey polycarbonate with hinged cover. NEMA 4X | ||
| Sensor Type | Catalytic Combustion | Galvanic Cell | Electrochemical |
| Life Expectancy | 1 to 2 years normal service | 2 years normal service | 2 years normal service |
| Dimensions | Height 8.5" (216 mm) Width 7.0" (178 mm) Depth 4.3" (109 mm) | ||
| Sampling Method | Sample draw pump | ||
| Display | Flow meter, LED's for operational status; pilot, fail | ||
| Warranty | One year, materials and workmanship | ||
![]()
| Part # | CO 35-3000RKA-CO | HC 35-3000RKA-HC |
|---|---|---|
| Min Operating Voltage | 23 VDC | |
| Max Operating Voltage | 30 VDC | |
| Max Current Draw | 200 mA | 250 mA |
| Signal Output | 4 mA at 0 ppm CO 20 mA at 300 ppm CO | 4 mA at 0 ppm 20 mA at 500 ppm Hexane. Linear. |
| Response Time | 30 seconds to 90% of concentration | |
| Operating Environment | ||
| Location | Indoor or outdoor | |
| Temperature | 30 to 120° F | |
| Humidity | 0 - 99% RH, non condensing | 5 - 95% RH, non condensing |
| Housing | Wall mounting grey polycarbonate with hinged cover. NEMA 4X | |
| Sensor Type | Electrochemical | Metal Oxide Semiconductor |
| Life Expectancy | 2 to 3 years normal service | 5 to 10 years typical |
| Dimensions | Height 8.5" (216 mm) Width 7.0" (178 mm) Depth 4.3" (109 mm) | |
| Sampling Method | Sample draw pump | |
| Display | Flow meter, LED's for operational status; pilot, fail | |
| Warranty | One year, materials and workmanship | |