| Split Pipe | Direct Bury Pipe | Bends and Couplers |

A new and innovative Flanged Maintenance Pipe (FMP) system that will save time and money.
Flanged Maintenance Pipe (FMP) has been primarily developed to
replace split steel or other types of split duct materials in underground
applications. It is superior to all others for this application because it
has been engineered to work with existing underground utility conduit. This
is the only engineered split system with an inside diameter to match the
outside diameter of utility conduit.
FMP is a two piece flanged trough or duct basically used as mechanical protection
for pipes, wires, cables or other services in both underground and on the surface
applications. This ingeniously simple design lends itself to a wide variety of
applications. Installers appreciate how easy it is to work with.
Unlike other engineered split duct systems, FMP does NOT have a belled end. There
is no need for it because the inside diameter matches the outside diameter of
utility conduit. This also eliminates the need for couplings to attach to the
utility conduit. This feature of FMP greatly speeds up the process and reduces
time, labor and costs during installation.. The staggered joint system totally
eliminates the use of couplings in straight runs. The resulting conduit is so
strong that it can literally be picked up and moved after assembly if/when necessary.
FMP was engineered to take advantage of the two piece sectional design which
enables, when necessary, the placement of additional cable and services. Stainless
steel fasteners (included with FMP) will insure easy entry for future access
if/when necessary. The inside diameter of the FMP is roughly fifteen percent
larger than that of the conduit it is repairing or replacing. The larger inside
diameter makes it much easier to lay in those extra cables or services.
FMP’s flanges can be used for hanging and supporting at suitable points.
The flanges have slotted holes for easier assembly. The flanges can also be used
to support additional runs of duct to extend the number of ducts in a horizontal
or vertical run. The resultant duct run is incredibly strong.
FMP comes standard in Galvinized Steel Pipe (GSP) and is also available upon
request in Black Steel Pipe (BSP). Sizes range from 2” to 6”. To
accommodate the staggered assembly the standard lengths come in 5’ and
10’ sections (custom lengths available upon request). The wall thicknesses
are available in .137’, .188” and .250”. Our lightest wall
is significantly heavier than other flanged split duct systems on the market.
Why? Our research revealed that anything thinner (say a 14 gauge wall) is exposed
to a much greater risk of a backhoe bucket tooth piercing through the thin metal.
The results to the cable would be disastrous!
Applications
- FMP Installations
Bridge crossings
Utility entrances
Pole risers
Surface and underground
Temporary and emergency repairs
Enclose and protect other line services
Telephone Duct repair
Industrial plant services
Anywhere cabling needs would require future access
Anywhere mechanical protection is neede - FMP Advantages
Adapts perfectly to IPS conduit
Mechanically superior to other designs
Largest range of safe wall thicknesses and sizes for direct bury applications.
Stainless Steel Fasteners for assured future re-entry.
Allows for future capacity or design upgrades
Installs fast, saves time and labor costs
Provides quick protection to exposed services
Meets utility needs for mechanical protection
Flanged sections provide own hanre

See Flanged Maitenance Pipe (FMP) Direct Bury Here
See Bends and Couplers Here